USER CODES
User Code Level: 9
Function: To add and delete user codes
User Codes is used to add and delete the user codes programmed
into your alarm system. Up to 32 different user codes may be
available. Each user code consists of four assignments; the user
number, the user code, the code level, and the area access.
User Number: A number from one to 32 which identifies the
person using
the code. This number is transmitted to your
central station
on various system reports. User number one
may be used
as an Ambush Code. Any time this code number
is used an
Ambush signal will be transmitted to your central
station.
This function is optional and is programmed dur-
ing system
installation.
User Code Level
Menu Options 1 2 3 4 5 6 7 8 9
Door Access * * x x x x x x x
Fire Reset * * x x x x x x x
Arm/Disarm * x x x x x x x
Alarm Silence * x x x x x x x
System Test x x x x x x
Loop Monitor x x x x x x
Outputs On/Off x x x x x
Bypass loops, Extend x x x x
Schedules x x x
Set Time x x
Remote Authorization x x
User Codes x
* only during permanent or temporary schedules
23
31
REMOTE AUTHORIZE
Step By Step:
1. Press until REMOTE AUTHORIZE is displayed.
2. When REMOTE AUTHORIZE is displayed press any one of
the
top four select keys. The display will read ENTER CODE: - .
3. Enter your code number and press . The dis-
play will
read AUTHORIZED - - 1 HR .
User Code Level: 8
Function: Authorizes remote functions for one hour.
Remote Authorize is used to give your central station access to your
alarm system for remote programming and commands. When
remote authorize is selected you will be asked to enter your code
number, when the code number is accepted the central station will
have access to your system for one hour.
COMMAND
COMMAND
Code Number: A one to five digit number which is used
to arm, disarm and
gain entry to the various menu options. This code
number
cannot begin or end with zero.
Code Level: The first digit of the five digit code number which
defines the
level of menu options available to that code.
Area Access: The area numbers which may be armed or dis-
armed by a
code number. One to four areas may be available
in your
system. Each User Code can have a different
combination
of areas assigned to it. (NOTE: Area Access
does not
function on all/perimeter systems.)
Kommentare zu diesen Handbüchern